Avid Technology MOS Gateway Spécifications Page 93

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 152
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 92
MOS Gateway Configuration File
93
A Path text field specifies the queue in the iNEWS database to which
media object metadata will be replicated. The queue’s pathname
appears in the Directory column of the MosAdmin application and in
between the <path> and </path> tags in the configuration file.
Figure 6 MosAdmin Replication Tab
To configure replication for a device:
1. Select the device from the list on the Replication tab in the MosAdmin
window.
2. Select the trigger type—either manual or scheduled. If scheduled is
selected, continue to step 3; otherwise, skip to step 4.
3. Set a replication time—this is the time replication is set to occur each
day, if the scheduled trigger type is selected.
4. Select the Clear Queue check box to clear the iNEWS queue before
replication. Checking the box is recommended.
5. Type the path to the device’s queue—created on the newsroom
computer system—where the replicated MOS objects will be placed.
Vue de la page 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 151 152

Commentaires sur ces manuels

Pas de commentaire